SPECIFICATIONS
Method: rapid determination of cardiac markers troponin T, myoglobin and D-dimer from a single whole blood samples - reflection-photometric method
Measuring time: 8- 12 minutes -
Sample volume: 150 ml -
Working conditions: temperature 18 - 35 ° C; relative humidity 20 - 80% -
Memory: 20 values with time, date, patient data and the user, control 20 reading, 62 IQC results, 15 lot codes -
Dimensions: 173.2 x 124.5 x 44.5 mm -
Weight: 0,454 kg -
Power: 100- 240; 50-60 Hz -
: Tests
: Cardiac M Myoglobin
Quantitative determination of myoglobin in venous whole blood -
The reaction time 8 minutes -
Measuring range: 30-700 ng / ml -
Cut-off: 70 mg / ml -
: MYoglobin
is an earlier indicator of acute myocardial infarction -
enables the detection of acute myocardial infarction within 6 hours after the onset of symptomsa -
: Cardiac T Quantitive
Quantitative determination of cardiac troponin from heparinized venous whole blood -
Reaction time: 12 minutes -
Measuring range 0.1-2.0 ng / ml -
Cardiac reader reported results between 0.03 ng / ml and 0.1 ng / ml -
Cut-off: 0.1 ng / ml -
: Troponin T
Is specific to cardiac muscle -
Offers wide possibilities of diagnostics -
Confirmation of suspected myocardial infarction -
Establishment of risk in unstable angina pectoris -
Detection of minor myocardial damage -
Detection of myocardial damage even 10-14 days after emergence -
: Cardiac D-Dimer
Quantitative determination of D-dimer from heparinized venous whole blood -
Reaction time: 8 minutes -
Measuring range: 0.1 to 3.0 mg / ml -
Cut-off: 0,5μg / ml -
: D- dimer
indicates the occurrence of deep vein thrombosis and pulmonary embolism -
: Cardiac proBNP
Quantitative determination of NT proBNP from heparinized venous whole blood -
Reaction time: 12 minutes -
Measuring range: 60 to 3000 pg / ml -
Easy to use
.The instrument guides you through the measurement process in steps
Insert a test strip into the instrument and press START 1
Apply 150 μl of heparinized whole venous blood on the strip 2
When the reaction is complete, read the results (the results can also be printed using the appropriate printer) 3
Cardiac Reader analyzer for quantitative determination of troponin T, myoglobin and D-dimer
Compact, portable instrument that does not take much space -
Always ready for use (stand-by-mode) -
No manual calibration -
All the necessary information concerning the measurement operation are entered automatically using the code chip -
No additional processing of the sample -